Payments and Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Description
Voltage:
- Up to 600V, DC or peak AC
- Up to 420VAC RMS sinusoidal
- Better than 0.5% accuracy DC
- Better than 1.0% accuracy AC for harmonic content below 1kHz
- >10 Megaohm input impedance
High Precision Voltage:
- Up to 100mV with <15nV per count resolution
- Up to 1.2V with <200nV per count resolution
- >10 Megaohm input impedance
Current, Internal:
- Up to 10 Amps
- 20 µV / mA burden voltage (using factory fuse)
- Less than 5 µA per count in 10 Amp scale
- Better than 1% accuracy
Resistance:
- Better than 1% accuracy over 20 Ohms – 20 Megaohms
Frequency:
- Better than 1% accuracy up to 1kHz
Diodes:
- Up to 1V @ 100nA
Sampling:
- 8kHz dual simultaneous sampling
- 4kHz analog bandwidth for most measurements
- 24-bit resolution max
- >18 Effective bits at 125 samples per second
On Board Storage – SD Card:
- MicroSD Card
- Up to 32GB, More than a week of constant logging two channels at 8kHz
- SD or SDHC (not SDXC)
Radio:
Protocol: Bluetooth Low Energy
GATT Profile: To be released in 2014
Wireless Range:
The wireless range has been tested empirically through the following media to an iPhone 5.
- 50m air, line of sight
- 5cm of refrigerator, door closed
- 1m of 2006 Honda Civic – Engine compartment to the passenger seat
- 10m air + safety shield of a Tesla Coil rock bands testing facility
Applications:
Power:
Simultaneous high-speed sampling of voltage and current gives the following power measurements:
- True Power
- Reactive, Complex, Apparent Power
- Power Factor
- Total Harmonic Distortion
- Phase Lead or Lag
Impedance:
Measure the supply sag under the load to estimate:
- Supply or Battery equivalent resistance
- Battery State of Health
Current Measurement, External Shunt:
- Measure thousands of amps with sub-milliohm shunts
- Measure precision currents with large shunts
- Use the existing wiring for “quick’n’dirty” measurements
- Use 1′ of 10 AWG for 12µA per count resolution, up to several times the wires ampacity.
Temperature:
- External Thermistors, Steinhart-Hart or Beta parameterized
- External Thermocouples
- Internal ambient temperature sensor